Characteristics of a Structure-Foundation System
The dynamic characteristics of the structure-foundation system of a 1/4 -scale nuclear power plant containment model is studied using seismic records. The model structure is treated as...
Modal Parameter Identification of an Offshore Platform from Earthquake Response Records
The Whittier Narrows earthquake on October 1, 1987, was recorded by the earthquake monitoring system on an offshore platform installed in a water depth of 97 m in the Santa Barbara Channel....
Tradeoffs Between Active Control and Identification of Structural Systems
This paper explores the tradeoffs between structural identification and structural control in a quantitative manner. Through the intemediary concept of an optimal input, it is shown that...
Strong-Motion Records from Buildings
Since the establishment of the California Strong Motion Instrumentation Program in 1972, over 90 buildings have been instrumented extensively to measure their response during earthquakes....
Some Significant Records from Instrumented Structures in California?USGS Program
The main objective in seismic instrumentation of structures is to facilitate response studies that lead to improved understanding of the dynamic behavior and the potential for damage to...
Seismic Instrumentation and Its Implication for High-Rise Buildings in Japan
An outline of the present state of the strong earthquake motions observation systems in Japan and an example of the obtained records of an earthquake and its simulation analysis of a high-rise...
Seismic Instrumentation of Buildings in Italy
The paper describes the philosophy of the ENEA project of seismic instrumentation of buildings in Italy and the steps made to implement it. The philosophy is twofold: i) to define a general...
Seismic Evaluation of a Tall Reinforced Concrete Frame Building
Accelerations at basement, fifth and tenth floor levels of a reinforced concrete apartment building were recorded during the October 1st, 1987 Whittier-Narrows earthquake. These accelerations...
Seismic Evaluation of PG&E Concrete Dams
Seismic evaluation of PG&E concrete dams is an ongoing process. The seismic environment for the dams changes over time because more historical earthquake data is obtained, faults...
Ductility and Failure Characteristics of Concrete and Rock Subjected to Complex Load Paths
Strength, ductility and the complex material response features of concrete and rock should be evaluated through carefully planned material properties test programs designed to subject...
Earthquake Induced Cracking in Concrete Gravity Dams
An important nonlinear behavior in the earthquake response of concrete gravity dams is the formation and propagation of tensile cracks in the concrete. The earthquake response of a typical...
Building Frames Subjected to 2D Earthquake Motion
Inelastic response of a simplified model of a 10-storey building frame was analyzed to assess the effects of bi-directional seismic loading. Interaction between the strengths in the two...
Seismic Large Amplitude Liquid Sloshing?Theory
The sloshing phenomenon in seismically-excited, rectangular, liquid storage tanks is addressed. In particular, a semi-analytical method to study the effects of large amplitude sloshing...
Buckling Criteria for Earthquake-Induced Overturning Stresses in Cylindrical Liquid Storage Tanks
Perhaps one of the most common forms of seismic damage to cylindrical liquid storage tanks made out of steel is buckling of the tank wall due to vertical overturning stresses. Buckling...
Static Tilt Analyses of Uplifting Cylindrical Tank
This paper describes the general method adopted for predicting the static tilt performance of cylindrical liquid storage tank that is free to uplift. In the analysis described here, the...
Detection of Seismic Structural Damage
Damage analysis models based on equivalent modal parameters are used to identify the serviceability limit state for structures subjected to earthquake loads. A model for the analysis of...
Seismic Performance of Existing Building in New York City
Strength-based damage indices depending on structural shear capacity and earthquake intensity are used to predict the seismic performance of existing buildings in New York City. Nonlinear...
Biaxial Damage Assessment
The structural system under investigation is a frame subject to seismic excitations. The analysis accounts for the spatial distribution of beams, columns and bracing system. It also considers...
Normalized Damage Index for Evaluation of Buildings
A conceptual model for evaluation of structural damage is developed based on the fundamental idea of demand and capacity. The proposed formulation combines two recognized sources of damage:...
Seismic Vulnerability and Retrofitting of Buildings. Recent Experiences in Mexico City
Measures taken in Mexico City after the 1985 earthquake to evaluate the safety of existing buildings, to strengthen damaged structures and to retrofit those that were considered to need...
Return to search