Seismic Risk and Decision Analysis of Lifeline Systems
This paper provides general guidelines for performing lifeline seismic risk and decision analyses. Relevant input models are introduced as they support the performance of component and...

CSMIP Strong-Motion Instrumentation and Records from Transportation Structures?Bridges
Seven transportation structures have been instrumented by the California Strong Motion Instrumentation Program (CSMIP), including four bridges. Records (in excess of 0. 25 g maximum acceleration)...

Seismic Design of Airport Control Towers
The paper describes state-of-the-art design in seismically active areas. It includes a review of current code design parameters and specific tower design criteria. Tower design examples...

Port of Seattle Seismic Waterfront Design
This paper describes the soil seismic design process, using the design developed for a concrete apron project at Terminal 20 as an illustration. Damage by the 1965 earthquake is described....

Seismic Response of Port and Harbor Facilities
A research program compiled information regarding the behavior of port and harbor facilities during past earthquakes. The potential for significant damage to port and harbor facilities...

Intermountain Power Project Seismic Design
Coal-fueled generation units of the Intermountain Power Project are constructed in a seismically active area of Utah (UBC Zone 3). The seismic design criteria were published during the...

An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...

Seismic Risk and Reliability of Telecommunications Systems
A general method for seismic risk analysis of telecommunications sytems evaluates by statistical means the earthquake environment and the earthquake vulnerability and effects on the system...

A Systematic Approach to Conducting Seismic Margin Reviews for Nuclear Power Plants
Deviations from the current codes and standards are considered acceptable in a SMR in areas where the design criteria impose significant conservatism provided the intended function of...

Response of Subsystems on Inelastic Structures
Preliminary analyses are performed to obtain insight into the seismic response of subsystems supported on simple structures that yield during severe earthquake ground motions. Current...

Seismic Qualification of Main Control Boards by Combined Mathematical Model and In-situ Modal Test
By adjusting the stiffness of the model, mode shapes and frequencies can be matched to those from the in-situ tests, thus giving a verified and representative model. With the verified...

Seismic Evaluation of Non-Seismically Designed Existing Magnox Nuclear Power Plants
Special procedures included on-site testing with a portable shake table, low vibration testing using a structural dynamics analyser, and on-site inspections. The low vibration testing...

A Summary of the Seismic Qualification Utilities Group (SQUG) Program
In 1980, the Nuclear Regulatory Commission (NRC) designated Unresolved Safety Issue (USI) A-46 to address the seismic safety of equipment in operating nuclear power plants. In 1982, the...

Pipe Impact on Concrete Slabs
A series of pipe impact on concrete slab tests have been performed at the CEA's Cadarache Laboratory using the AQUITAINE II facility. The testing program was jointly sponsored...

Probabilistic Analysis of Impact Loading Conditions
Probabilistic methods are developed for the analysis of random impact loading conditions that arise from oblique, noncollinear, and spinning missile impacts. Models are developed for the...

Low Velocity Impact Tests on Reinforced Concrete Panels
The results of low velocity impact tests on reinforced concrete panels are presented. These tests were conducted to investigate the behavior of reinforced concrete flexural elements subjected...

Behavior of an Operating Floor Subjected to Heavy Load Drops
A structural evaluation of the behavior of a Boiling Water Reactor operating floor subjected to postulated heavy load impact is presented relative to the evaluation of nuclear industry...

Sensitivity of Peak Dynamic Responses to Input Factors
Responses have been calculated for the Zion Unit 1 plant, using the SSMRP computer code SMACS, as part of the seismic probabilistic risk assessment performed by the Seismic Safety Margins...

Seismic Evaluation of Reinforced Masonry Walls
Masonry walls in operating nuclear plants are in many cases found to be overstressed in terms of allowable stresses when evaluated using current seismic design criteria. However, experimental...

Seismic Capacities of Masonry Walls at the Big Rock Point Nuclear Generating Plant
An evaluation to determine the ability of selected concrete block walls in the vicinity of essential equipment to withstand seismic excitation was conducted. The seismic input to the walls...

 

 

 

 

Return to search