Importance of Phasing of Strong Ground Motion in the Estimation of Structural Response
In this paper, the influence on Fourier phase spectrum of seismic source directivity due to rupture propagation along the earthquake source is investigated. The phasing is described using...

Dynamic Testing of Structures Using the RESCUE Technique
This paper describes the most recent phase of an NSF supported program at SRI International to develop the technique of repeatable earth shaking by controlled underground expansion (RESCUE)...

Pseudo-Dynamic Testing of Structural Components
The pseudo-dynamic testing procedure is a simultaneous simulation and control process in which inertia and damping properties are simulated and flexibility properties are acquired from...

Seismic Tests of Friction Damped Steel Frames
This paper presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames...

Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...

Precast Roofs for Blast Shelters
A shallow-buried reinforced concrete blast shelter has been constructed and dynamically tested at the U. S. Army Engineer Waterways Experiment Station (WES). Three thicknesses of precast...

Field Tests of Wind-Structure Interaction
The present study was initiated to investigate the possible causes for excessive lamp failure rates on High Mast illumination towers in the State of Minnesota. The study consisted of two...

Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...

Dynamic Tests of LNG Storage Tanks for Earthquake Analysis of Liquid-Tank-Pile-Soil Interaction
This paper presents a field test procedure for determining the dynamic properties of large liquid natural gas (LNG) storage tanks under operating conditions. Two methods of vibratory excitation...

Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...

Use of Vibration Tests to Determine Lateral Load Paths in Medium Rise Buildings
A structural system identification procedure is described in which an initial analytical model of a building is modified until it predicts accurately the mode shapes and natural frequencies...

Seismic Behavior of Long-Span Cable-Stayed Bridges
Special features of the earthquake-response analysis of cable-stayed bridges, subjected to multiple-support excitation, are presented including a basis for calculation of seismic forces...

Seismic Response Analysis of Two Major Bridge Structures
The seismic response analyses of two major bridge structures have been conducted. In these two bridges, portions of the piles are either submerged in the water or free-standing within...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...

Building Identification: Needs and Means
The need to conduct 'system identification' of existing buildings by nondestructive testing is discussed. A recommended flow-chart is exemplified. Existing dynamic...

Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...

Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...

Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...

Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...

 

 

 

 