ASTM C666 (A) Freeze-Thaw Durability of Air-Entrained Wet- and Dry-Mix Shotcrete
In order to assess the freeze-thaw durability of shotcrete, six samples of dry-mix shotcrete and one sample of wet-mix shotcrete were mixed outdoors at Hydro-Quebec's research institute...
Effect of First-Story Shearwalls on Earthquake-Resistant Buildings
A Practical system for earthquake-resistant building design is described. The system utilizes Teflon sliders at the top of the first story framed shearwalls to carry a portion of the superstructure....
Damage Assessment for Reinforced Concrete Buildings with Shear Walls
This paper tries to establish the analytical method of damage assessment for R.C. buildings with shear walls before or after earthquake. Incremental nonlinear spectrum analysis, using...
Welded Wire Confinement Grids
The invention of a new way to reinforce concrete using high strength welded wire grids, (WWG) increases its earthquake resistance by improved ductility and also opens the way for vast...
CenterCore Strengthening System for Seismic Hazard Reduction of Unreinforced Masonry Bearing Wall Buildings
The CenterCore technique of reinforcing unreinforced masonry walls was developed with the help of a National Science Foundation grant in 1984. The CenterCore strengthening system consists...
Seismic Behavior of Weak-Column Strong-Beam Frames
An experimental evaluation of the seismic performance of moment-resisting steel frames using Weak-Column Strong-Beam joints is described. A simulated seismic response is imposed on five...
Seismic Behavior of High Strength Concrete Columns
Information on the ductility of high strength columns in seismic areas has been scarce. The available information is based mainly on small test columns subjected to monotonic concentric...
High-Strength Concrete Joints Under Cyclic Loading
This experimental investigation was undertaken to check the validity for high-strength concrete beam-column joints of recommendations made by ACI-ASCE (American Concrete Institute-American...
Orthotropic Rigidities of Curved Concrete Waffle Slabs
Analytical expressions are derived for predicting the flexural and torsional rigidities during the pre-cracking and post-cracking stages for horizontally- curved waffle slab structures....
Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...
Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...
Diagnosing Lateral Strength of Existing Concrete or Masonry Buildings
A research prospectus is presented for improving present methods of structural evaluation for concrete and masonry buildings. Specifically, the proposed research plan is limited to strength...
Seismic Strengthening for Structures in Regions of Low Seismicity
Most existing structures were not designed to today's seismic codes and standards, and in fact in low seismicity regions codes did not require seismic design until recently....
Axial Capacity of Concrete Infilled Steel Box Column with Biaxial Bending
The objective of this study was to investigate the feasibility of using the Bresler reciprocal load method to calculate the axial capacity of a concrete infilled steel box column subjected...
A Shear Transfer Model for Floor-To-Wall Connections in Concrete Masonry Structures
Based upon experiments conducted at the Univ of California, San Diego (UCSD) on floor-to-wall connections in concrete masonry structures, a constitutive model was developed for the overall...
Analysis of Masonry Walls with Smeared and Discrete Crack Models
To design modern reinforced masonry structures for seismic loads and to evaluate the seismic safety of existing unreinforced masonry buildings, the shear resistance of masonry shear walls...
An Innovative Connection Detail for High-Rise Buildings
Composite columns consisting of hollow steel tubes filled with high strength concrete have been used in high rise building construction in the USA and Far East Asian countries. The focus...
Behavior and Design of Angle Connections Subjected to Cyclic Axial Force and Shear
The objectives of this study were to establish cyclic behavior of double angle shear connections subjected to axial load and to develop design recommendations. Five cyclic tests of double...
Composite Beams and Joists
Composite beams and joists used as flexural members in multistory steel-frame buildings are considered. Research results have shown that present design values for headed shear studs, used...
Interaction Between Beam and Steel Connections
The overall objective of the investigation is to study the behavior of a particular steel connection type, flush end plate steel connections, subjected to shear, axial forces, and possibly...