Strength Evaluation of Existing Reinforced Concrete Structures
The load test as described in ACI 318-83 Chapter 20, entitled 'Strength Evaluation of Existing Structures,' was conducted at 60%, 80%, and 100% of the calculated...

Energy Approach of Earthquake-Structural Design Analysis
A new procedure developed from the earthquake energy concepts is presented in this paper. A short-squat building and a long-slender building are analyzed using the presented procedure....

Fourier Series Expansion on Determination of Response Bound of Beam
Fourier series expansion is suggested to discrete the continuous vibrating system by regarding Fourier constants as generalized displacement parameters. The orthogonal merit to the terms...

Aerodynamic Modeling of Chimneys
The wake induced acrosswind behavior of circular cross-section structures, such as industrial chimney, has been studied for many years using wind tunnel models. Due to the relaxation of...

Inelastic Response of Buried Pipelines Due to Landslide Effects
During earthquakes, a buried pipeline may experience significant loading as a result of large relative displacements of the ground along its length. Large ground movements can be caused...

Mitigation of Wind-Induced Vibration of Tall Buildings
This paper summarizes a detailed study of the sensitivity of building acceleration to changes in structural stiffness, mass and damping and to the eccentricities in the centers of stiffness...

Aerodynamic Methods for Mitigating Wind-Induced Building Motions
Excessive wind-induced motions of tall buildings most frequently result from vortex shedding induced across-wind oscillations. This form of excitation is most pronounced for relatively...

Dynamic Response of a Building with Dual System
The paper presents the dynamic response of a 30-story building with dual system consisting of cross-bracing and beam-column moment resisting frames. Two types of beam-column connections,...

Analysis and the Design of Multi-Layer Viscoelastic (V.E.) Dampers for Tall Structures
Vibrational motion of tall buildings can be damped by employment of viscoelastic passive dampers in the structure. The type of dampers selected depend on locations where relative displacements,...

Tuned Liquid Damper and Its Application to Tower-Like Structures
A new kind of damper, Tuned Liquid Damper (TLD) relying upon motion of, shallow liquid in a rigid container for absorbing and dissipating the vibrations energy is explained. The performance...

Local Wind Pressures on Roofs
The paper reviews the results of the most recent research studies in the evaluation of wind pressure coefficients for the design of roof cladding elements. The effect of roof geometry...

Wind Effects on Loose-Laid Cladding Systems
Modern roofing systems for flat roofs frequently make use of rigid insulation boards, gravel and concrete pavers that are loose-laid on top of the waterproof membrane. The authors have...

Wind Performance of Asphalt Roofing Shingles
Pre-seal and post-seal wind resistance of asphalt roofing shingles is discussed. A test method for evaluating pre-seal wind damage is described. Wind tunnel testing results are presented...

Ballasted Single Ply Design Guide Development
A new roofing concept called ballasted single ply has now captured about 25% of the new and retrofit flat roof market. This concept relies on the use of ballast to provide the wind resistance...

Seismic Response of Multistory Building Structures With Flexible Floor Diaphragms
An efficient model for three-dimensional analysis of multistory structures with flexible floor diaphragms is proposed in this paper. Three-dimensional analysis of a building structure...

Floor Response Spectra Including Structure-Equipment Interaction Effects
An efficient method for generating floor response spectra with the structure-equipment interaction effects is proposed. Floor response spectra are computed from a prescribed ground response...

Optimum RC Member Design With Discrete Sections
This paper concentrates on the development of simplified yet effective algorithm for optimum reinforced concrete (RC) member design. After constructing the data base of predetermined reinforced...

Flexural Strength of Ultra-High Strength Concrete Members
Various proposals have been made for the pridiction of strength of high strength concrete sections. One of the most important parts of any strength computation procedure is the assumption...

Full-Scale Measurement on Chiba Port Tower
Chiba Port Tower is a tall tower, 125m high, with a rhombus shaped plan. All of the surfaces are covered with half mirror glass. On the top of the tower, a 'Tuned Mass Damper'...

Unsteady Aeroelastic Base Moments on a High-Rise Building
To consider aeroelastic instabilities of prismatic structures in winds, i.e., vortex induced vibrations or galloping oscillations, unsteady aeroelastic forces must be investigated as the...

 

 

 

 

Return to search