Caisson
The Jamaica Bay Water Pollution Plant was renovated and upgraded from l973-l983 and included sinking a 116 ft. x 105 ft. caisson 50 ft. deep adjacent to city streets and buildings. The...

Hydro Power
The Kerckhoff 2 Hydroelectric Power Projects adds 140 MW to the capacity of the San Francisco area's Pacific Gas & Electric system. No new dam was needed; only a 4-mile...

Pipe Impact on Concrete Slabs
A series of pipe impact on concrete slab tests have been performed at the CEA's Cadarache Laboratory using the AQUITAINE II facility. The testing program was jointly sponsored...

Design for Whipping Pipe Impact on Reinforced Concrete Panels
This paper describes determination of local and overall effects on reinforced concrete panels due to whipping pipe impact in postulated pipe break events. Local damage includes the prediction...

Low Velocity Impact Tests on Reinforced Concrete Panels
The results of low velocity impact tests on reinforced concrete panels are presented. These tests were conducted to investigate the behavior of reinforced concrete flexural elements subjected...

Reliability Assessment of Indian Point Unit 3 Containment Structure Under Combined Loads
In the current design criteria, the load combinations specified for design of concrete containment structures are in the deterministic format. However, by applying the probability-based...

Seismic Capacities of Masonry Walls at the Big Rock Point Nuclear Generating Plant
An evaluation to determine the ability of selected concrete block walls in the vicinity of essential equipment to withstand seismic excitation was conducted. The seismic input to the walls...

Major Considerations in Scale Modeling of Reinforced Concrete Containment Structures
Reinforced concrete containment structures pose unique modeling problems, especially when leakage integrity is of interest. This paper presents a general discussion of modeling considerations...

Fluid Structure Interaction Analysis of a Concrete Suppression Chamber of Mark I Containment System
Recent studies have demonstrated that the interaction between a structure and fluid can have a significant influence on the response of the overall system when subjected to certain dynamic...

Development of Concrete Nuclear Containment (ACI 359) Code Requirements as they Relate to Probability Based Load
The historical development of the load combinations used in concrete containment is presented in the paper. These load combinations are examined and identified in the light of the reasonable,...

Stress Distribution Around the Equipment Hatch Opening of a Prestressed Concrete Containment for a PWR Power Station
Results are reported of a finite element stress analysis for the linear elastic deformation around the equipment hatch opening in prestressed concrete containment. The dimensions and form...

Containment Integrity of SEP Plants under Combined Loads
The containment designs analyzed consisted of three inverted light-bulb shaped drywells used in boiling water reactor (BWR) systems, and three steel-lines concrete containments and a spherical...

Onsite Storage Facility for Low Level Radwaste
The Tennessee Valley Authority (TVA) has designed and constructed an onsite storage facility for low level radwaste (LLRW) at its Browns Ferry Nuclear Plant in northern Alabama. The paper...

Safety Investigations of Existing Spent Fuel Storage Structures for Increased Spent Fuel Storage Capacity
Delays in the solution of disposal problems continue to create the need for additional on-site spent fuel storage capacity at commercial nuclear power generating facilities. Rod consolidation...

Evaluation of Non-Ductile Drilled-in Expansion Bolts
This paper provides background and justification for the design of closely spaced non-ductile drilled-in expansion bolts (bolts). It describes testing used to establish allowable design...

ACI 349 Embedments: Code Provisions and Methods of Analysis
Steel embedments form the critical link between steel and concrete structures. Appendix B of ACT 349, Code Requirements for Nuclear Safety Related Concrete Structures, specifies the ultimate...

Sodium Concrete Reaction ? Structural Considerations
An overview of the sodium concrete reaction phenomenon, with emphasis on structural considerations, is presented. Available test results for limestone, basalt, and magnetite concrete with...

Capability of LMFBR Plant Structures Beyond the Design Base
A study is presented concerning the capability of structures in a loop type Liquid Metal Fast Breeder Reactor Plant, the Clinch River Breeder Reactor Plant (CRBRP), to sustain conditions...

As-Built Locations Through Precision Photography
This paper describes a new application of close range photogrammetry as a technique for obtaining reliable as-built locations of embedded threaded inserts in concrete structures and the...

Design of Thin Wall Reinforced Concrete Pipe Using Dimension Ratio (DR)
Dimension Ratio is defined as the ratio of the internal pipe diameter to the pipe wall thickness. The Caltrans culvert research leading to the development and use of the Dimension Ratio...

 

 

 

 

Return to search