PCB Contamination of a Mass. Harbor: Technical Challenges for a Remedial Solution
The highest priority uncontrolled site in Massachusetts, the New Bedford Harbor Superfund site, is contaminated with high concentrations of PCBs. The magnitude and nature of contamination,...

In-Plant Testing for Evaluating Aeration Systems
In the fall of 1984, ASCE published a standard, Measurements of Oxygen Transfer in Clean Water. The standard, if used by the industry, should simplify evaluation of alternative aeration...

A New Approach to Activated Sludge Plant Design
Activated sludge plants are designed on the basis of stationary tests at laboratory scale for constant organic loads and constant input flows. From these tests the kinetic parameters are...

Measurement of Activated Sludge Rheology
Rheological measurements provide fundamental information on the physical properties of activated sludge. Such properties influence the behavior of activated sludge in wastewater and sludge...

Understanding Secondary Clarifier Behavior
The author has developed a graphic procedure for analyzing the hydraulic behavior of settling tanks. Data have been used in numerous cases to devise low cost in-tank and external improvements...

Impoundment Design for Precious Metal Tailings
An engineering study and design of impoundments for the disposal of mill tailings in central Nevada is presented. Mill process waste is generated as flotation tailings and cyanide residue....

Field Scale Solidification/Stabilization of Hazardous Wastes
The selection of appropriate remedial action measures only takes place after a full evaluation of all feasible alternatives. An alternative to off site disposal is solidification/stabilization...

Variable Leachate Treatment System: A Cast Study
This paper explores the experience of the authors in collecting data and designing leachate collection and treatment facilities at municipal sanitary landfills over the last several years....

Detection of Leakage Through Subsurface Barriers Using Guided Acoustic Waves
The primary method for preventing hazardous liquid and leachates from entering the groundwater is the use of a physical barrier. These barriers are susceptible to a number of mechanisms...

Anaerobic Treatment of Phenol: Degradability, Toxicity and Kinetics
Anaerobic biodegradation of phenol was demonstrated at up to 1000 mg/L in batch serum bottle studies and 1900 mg/L in anaerobic filters. In batch serum bottle studies, concentrations of...

Treatment of the Wastewater From the Alkaline Cooking of Maize in an RBC System
The liquid waste resulting from cooking and washing of maize is called nejayote or nexayote. The soluble COD concentration of this waste ranges from 10,000 to 20,000 mg/l. In an effort...

Land Treatment of API Separator Sludge
An extensive research project was undertaken to establish design and operational guidelines for treatment of oily sludge using land treatment systems. Forty-five test plots were established...

Land Treatment of Refinery Wastes
The authors discuss: waste characteristics; land treatment; and cost comparison with incineration....

Program for Control of Petroleum Refinery Wastewater
The Sanitation Districts of Los Angeles County (LACSD) provide wastewater treatment services to approximately four million residents and eight thousand industrial companies. Large and...

Relating Water Treatment Problems to O & M Factors
The author discusses the operations and maintenance factors that must be considered in dealing with water treatment problems....

Environmental Infrastructure: Does Civil Engineering Education Meet the Challenge?
The author explores some avenues for re-direction of the civil engineering education process to become more responsive to the needs of infrastructure re-development in the areas of water...

Operations, Maintenance & Cost Comparisons of Three Dewatering Devices
The Metropolitan Waste Control Commission's Wastewater Treatment Plant in Minneapolis/St. Paul has demonstrated that two new innovative sludge dewatering pocesses, namely,...

Belt Filter Operation and Maintenance Survey (ASCE-WPMC Subcommittee Report)
This report summarizes the results of a national survey of municipal wastewater plant belt press installations conducted by an ASCE Task Committee in 1984. Data from 106 installations...

Optimization of Variable Volume Diaphragm Filter Presses
The St. Paul, MN, Metropolitan Waste Control Commission Wastewater Treatment Plant has installed and operated eight variable volume diaphragm filter presses for four years. During this...

Controlling Factors in Vacuum Filter Performance
Changes in the processes at Milwaukee's Jones Island sewage treatment facilities required testing of the filterability of various mixtures of sludges. The main purpose of...

 

 

 

 