Failures and Problems with Lift-Slab Construction
This chapter provides an overview of failures and problems with lift-slab construction. Topics include jack systems with inadequate take-up devices; the Canadian wedge connection; Serra...
Initial Considerations
The purpose of this section is to aid the line designers in developing their specifications for fiber-reinforced polymer (FRP) materials utilized in electric overhead line structures....
Materials and Manufacturing Processes
This chapter introduces the basic materials used in the manufacturing of composite structures. It will help the line designer in understanding how the different elements of the fiber-matrix...
Design Loads
This chapter discusses the types of loadings that should be considered when designing overhead power lines utilizing fiber-reinforced polymer (FRP) poles. For infrastructure applications...
Performance-Based Criteria for FRP Products and Materials
In most ways, fiber-reinforced polymer (FRP) structures perform similar to wood and steel structures. There are, however, certain differences and these differences are described in this...
Assembly and Erection
This chapter is intended to provide recommendations on transporting, handling, assembling, and erecting fiber-reinforced polymer (FRP) poles. An important consideration is that FRP poles...
Evaluation of the Geo-Con Vert Wall System
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center This report describes a HITEC evaluation designed...
Structure as Art
The structural engineering to support the architecture of a free-form, Frank Gehry-designed building is never easy, but the engineers for a new university building devised several innovative...
Evaluation of the Inter-Lok Retaining Wall System
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed...
Breakwaters '99
First International Symposium on Monitoring of Breakwaters
The papers present state-of-art methods and technologies that are used in the structural and environmental monitoring of rubble mound breakwaters. Structural monitoring concerns the structural...
Evaluation of the Tricon Retained Soil Wall System
Prepared by the Highway Innovative Technology Evaluation Center, a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to...
Recent Advances in Optimal Structural Design
Sponsored by the Technical Committee on Structural Design of the Technical Administrative Committee on Analysis and Computation of the Technical Activities Division of the Structural Engineering...
Evaluation of the Maccaferri Terramesh System Retaining Wall
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed...
A Dam for a Dam
The General Electric (GE) Dam in Minneapolis, Minnesota, was more than a century old when it began leaking excessively in December 1998. Operations staff for the dam owner�the Minneapolis-based...
Preserving Pisa's Treasure
Pisa's bell tower, a prime example of Romanesque architecture, would be renowned even if it did not lean. Construction of the tower began in 1173 and was not completed until...
Metamorphosis
Ranked as one of the 15 tallest buildings in New York, the headquarters of the Bear Stearns Companies, Inc., is a 45-story skyscraper that is 815 ft (248 m) tall. Replacing an existing...
The Excavation
As the largest, most emotionally charged deconstruction effort ever undertaken in the United States comes to a close, the World Trade Center has been reduced to what it was 35 years ago:...
Countering Chemical and Biological Terrorism
Prior to the terrorist attacks of September 11, building protection related to terrorism primarily focused on the threat of bombs detonated inside vechicles. However the September 2001...
The Chernobyl Problem
When the infamous accident at the Chernobyl Nuclear Power Plant occurred in April 1986�a catastrophe that involved an explosion that blew off the top of one of the plant's...
Dissecting the Collapses
The September 11 terrorist attacks on the World Trade Center horrified the civilized world. An estimated 2,830 human lives were extinguished by these attacks. In the aftermath of the events,...