Compressibility for Sand Under One-Dimensional Loading Condition
Empirical equations for one dimensional compression of sand do not include parameters characterizing properties of sand grains (e.g. moduli, size and shape of sand grains, and friction...
Settlement of Dynamically Compacted Deposits
This paper compares predicted and measured settlements of deposits that were densified by means of dynamic compaction. Settlement records are presented for sites consisting of old, midage,...
Stress-Deformation Behavior of an Embankment on Boston Blue Clay
An 11 m high I-95 embankment was thoroughly instrumented with piezometers, settlement rods and inclinometers to measure the behavior of the underlying 40 m thick deposit of Boston Blue...
Pilot Test on Groundwater Organics Removal by Low-Pressure Membranes
A 1-year membrane pilot study has been performed to evaluate disinfection-byproduct (DBP) precursors and color removal by low-pressure membranes from groundwater with color values up to...
A Probability Based Approach to the Design and Operation of Soil Vapor Extraction Systems
Soil vapor extraction (SVE) or soil venting is related with Monte Carlo simulation of critical soil characteristics. The correlation yielded a probability based nomograph that may be utilized...
In Situ Treatment of VOCs by Recirculation Technologies
Confronted with contaminated land from the world wars and the postwar industrialization period, German researchers and practicing professionals have worked to develop processes for effective...
Hydrodynamic Forces in Hydraulic Jump Stilling Basins
The knowledge of hydrodynamic forces acting on hydraulic jump stilling basin slabs has been a research topic for the past four decades. Published methodologies for computing the hydrodynamic...
Eliminating Water Column Separation and Limiting Backspin at a 12,000-Horsepower Pumping Plant
Milwaukee's Water Pollution Abatement Program includes a deep tunnel system which collects combined sewage and street runoff during storms for later treatment when capacity is available...
Pressure-Time Flow Rate in Low Head Hydro Plants
Very few methods are accepted for measuring the flow in the large intakes typical of low head, run-of-the-river hydro plants. These intakes are characteristically short, non-uniform, non-prismatic,...
The Use of Piezoelectric Film in Cavitation Research
A research program was conducted at the St. Anthony Falls Hydraulic Laboratory to investigate impulse pressures caused by the collapse of transient cavitation bubbles. The impulse pressures...
Non-Intrusive Experimental Setup for Inflatable Dam Models
A method which allows for a non-intrusive evaluation of the dynamic response of the inflatable dams under overflow and impounding water conditions is presented. The internal pressure variations...
A Computer-Controlled, Precision Pressure Standard
The operating principles as well as the technical aspects of the implementation of a precision pressure standard are presented here. The instrument can have dual use: either as a pressure...
Nonlinear Hydrodynamic Pressures on Arch Dam Faces
A finite difference method was used to calculate the nonlinear hydrodynamic pressures on the rigid arch dam faces. The arbitrary reservoir shapes were transformed to a regular cubic by...
Hydraulic Model Studies of Recessed Curb Inlets and Bridge Drains
A large hydraulic model (64 ft long by 10.5 ft wide) was used to test several geometries of recessed curb inlets and three types of bridge drains. Testing was at 3/4 scale for the recessed...
Force and Pressure Measurements in Spillway Plunge Pools
Plunge pools are often used to dissipate energy from high head spillways with flip bucket terminal structures. Conventional design of plunge pools has been based on a program of mobile...
Analysis of Selected Prototype Wave and Runup Data
An investigation of wave runup using video camera technology at Duck, N.C. is discussed. Results are provided from a subset of the runup experiment and wave runup level probability density...
Velocity Control Rings for RC Pipe on Steep Slopes
This paper discusses the use of internal concrete rings to reduce velocity and concrete erosion for reinforced concrete pipes on steep slopes in the Southern California area....
Laplace Valve Stroking for Complex Piping Systems
LaPlace valve stroking to control water hammer is applied in complex piping systems with friction and without friction. Two types of system are analyzed. The law of operation of the valves...
Considerations in 2-D Modeling of Hydraulically Steep Flow
Simplifications in the equations used to describe shallow water flow lead to some difficulties in modeling supercritical flow. The hydrostatic assumption produces two significant differences...
Standard Practice for Direct Design of Buried Precast Concrete Pipe Using Standard Installations (SIDD)
This publication, Standard Practice for Direct Design of Buried Precast Concrete Pipe Using Standard Installations (SIDD), (ASCE 15-93), is applicable to buried concrete precast pipe intended...