Application and Recent Development of a Numerical Model for Composite Beams with Partial Shear Connection
This paper deals with numeric analysis of composite steel and concrete beams for loads up to the ultimate beam capacity. Two versions of a numerical model are presented addressing such...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

Composite Walling
This paper describes a study into a system of walling that comprises two skins of profiled steel sheeting infilled with concrete. During construction the steel sheeting acts as permanent...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

The Definition of a Short Composite Column
A `short' column in composite construction is defined as one which can be designed for its cross-section strength alone without the need to consider stability effects. An extensive study...

Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...

Force Transfer in Composite Columns
The force transfer from steel to concrete without mechanical transfer devices in composite columns at points of load introduction is studied. A mechanism of force transfer and the factors...

New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...

Behavior of Unbonded Braces Restrained by Reinforced Concrete and FRP
A new composite steel brace called an unbonded brace (UB) is proposed to enhance the capacity of a steel brace to carry a compressive load of almost up to the yield strength of the steel...

Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...

Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...

Trenchless Diversity Fuels Growth of Construction Activities
This paper describes a variety of trenchless technology methods of reconstructing America's decaying pipeline infrastructure by using minimum and /or 'no-dig processes'. The decay of our...

Microtunneling with PVC Pipe
PVC is a suitable and economical product for sewer system construction. However, in the past, utilization of PVC sewer pipe in microtunneling was impossible due to axial thrust load limitations...

Joint Outfall H Relief Trunk Sewer System
The Joint Outfall 'H' Relief Trunk Sewer System consists of the construction of 11.3 kilometers (7 miles) of polyvinyl chloride lined reinforced concrete pipe varying in diameter from...

Installing a Raw Water Line by Microtunneling
Construction began in 1991 on a new water treatment plan for the Towns of Cary and Apex, with B. Everett Jordan Lake as a water source. Installation of two 1,400 mm raw water lines approximately...

The Ivie Pipeline Delivering Water to West Texas
The Ivie Pipeline is a $76,000,000 - 156-mile long water pipeline being constructed in West Texas. This paper describes highlights of the planning, design, and construction phase....

Reinforced and Prestressed Concrete Pressure Pipe Diagnosis
Prestressed and reinforced concrete steel cylinder pipes are used for transmission mains, water intake lines, sewers force mains. Many collapses caused by the steel cylinder attack were...

Relocating a 54-Inch Diameter Force Main without Interrupting Wastewater Flow
The City of Tampa, Florida, was faced with the challenge of relocating three segments of an old 1372 mm (54-in.) diameter reinforced concrete pipe force main, totaling nearly a mile in...

Gas Pipeline Fitness-for-Service Investigation
A delta reclamation district's plan to add significant fill on their levee caused great concern for the integrity of a critical PG&E 22-inch (559 mm) gas transmission line which...

 

 

 

 

Return to search