Moment Rotation Curves for Double Framing Angles
Moment-rotation curves for bolted framed steel connections are derived from force-deflection data obtained from laboratory tension and compression tests of angle segments. These derived...
Practical Analysis of Flexibly-Connected Building Frames
Modeling of flexible connection behavior as elastic-perfectly plastic is proposed for analysis of building frames, and results based on this idealization are compared with fully non-linear...
Centrally Loaded Columns
The paper has given a detailed description of the chapter on centrally loaded columns that will appear in the 4th Edition of the Structural Stability Research Council 'Guide...
Circular Tubes and Shells 4th Edition of SSRC Guide
The 3rd edition of the Guide was the first to have a chapter devoted to Cylindrical Tubes and Shells. Chapter 14 in the 4th edition is a major revision of Chapter 10 in the previous edition....
Effect of Connector Spacing on Double Angle Compressive Strength
The 1986 AISC 'Load and Resistance Factor Design (LRFD) Specification for Structural Steel Buildings' includes new rules affecting the design of built-up members...
Fracture-Mechanics-Based Fatigue Life Estimate
Fatigue lives of tee-shaped weldments are estimated using fracture mechanics concepts and crack growth rate data. Fracture mechanics is used to develop an approximate expression for stress...
Dynamic Fracture Toughness of Rail Steels
As new premium alloy rail steels exhibit increased wear resistance and as track lubrication is used, the failure mode for rails is shifting from wear to fatigue. Elastodynamic finite element...
Fatigue Design Criteria for Welded Steel Details
A review of fatigue data and reassessment of the 1983 fatigue specification resistance functions has been conducted. Since the AASHTO specification fatigue resistance provisions were introduced...
A Fatigue Study of Prestressing Strand
Strand fatigue data reported in the literature and also from recent tests were combined to form a data base of strand fatigue data which was analyzed using regression analysis techniques....
Fatigue Strength of Welded Wire Fabric
Long life fatigue tests were made on 12 concrete slabs reinforced with large diameter, Grade 75, deformed welded wire fabric. The specimens simulated, to full scale, conditions in a bare...
Base Isolation for Reinforced Concrete Structures
A recent experimental program has been carried out at the Earthquake Simulator Laboratory of the Earthquake Engineering Research Center in which a 1/5th scale reinforced concrete structural...
Thin Precast Fiber Reinforced Cement Panels
This paper provides an overview of some current applications, manufacturing methods, and physical properties of thin fiber reinforced cement board products currently produced. Many of...
Polymer Concrete for Structural Applications
Polymer concrete (PC) has been used extensively in the United States primarily as a repair material for portland cement concrete. The excellent flexural and compressive strength durability...
Concrete Shell Design for Membrane Stress
A methodology is presented which covers the design of reinforced concrete shells for membrane stress. The methodology follows the strength design method of the ACI 318-83 Building Code...
Large Reinforced Concrete Active Reclaim Silos
The design and construction of large reinforced concrete shell silos used to provide economical short-term protected storage for coal and lignite in the active reclaim systems of power...
Ultimate Membrane Strength of R/C Shell Elements
The ultimate strength of reinforced concrete shell elements is governed by the yielding of steel and/or the compressive strength of concrete. Depending on which of these two conditions...
The Ultimate Load Design Method of R/C and P/C Shell
Based on the testing results of 20 full size shells and models, the ultimate load analysis method is proposed to design four different kinds of reinforced concrete shallow shell structures....
Practical Application of PR Connections and Second Order Analysis
In the present LRFD Specifications type PR (Partially Restrained) connections are described as those where the connections of beams and girders possess an insufficient rigidity to hold...
Design of Steel Buildings for Second Order Effects
Several methods of calculating corrected effective length factors for unbraced frames are presented and discussed. In addition, an alternate format is suggested for the ASD beam-column...
Second Order Analysis of a 47-Story Building
A modern day second order analysis and ultimate strength review is made of a hypothetical 47-story unbraced frame designed under the 1969 AISC Specification. The original design is part...
Return to search