Caissons in Uplift in Sandy Soils
This paper describes the results of 10 full scale pullout tests conducted on short rigid caissons. Diameters ranged from 30 to 34 inches (760 to 860 mm) and lengths from 7 to 10 feet (2.1...
A Lateral Load Test on Seven Foot Diameter Caissons
Seven foot (2.1 m) diameter caissons (drilled shafts) were designed to support a mainline eastbound bridge and an off-ramp of Interstate Highway 70 in Glenwood Canyon, Colorado. A lateral...
Interpretation of Load Tests on Drilled Shafts?Part 1: Axial Compression
Existing interpretation methods for axial compression load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A simplified method,...
Interpretation of Load Tests on Drilled Shafts?Part 2: Axial Uplift
Existing interpretation methods for axial uplift load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method, which fulfills...
Interpretation of Load Tests and Drilled Shafts?Part 3: Lateral and Moment
Existing interpretation methods for lateral and moment load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method is proposed...
Bearing Capacity of Shallow Strip Foundation on Strong Clay Underlain by Weak Clay
Laboratory model test results for the ultimate bearing capacity of shallow strip foundations supported by a stiff clay layer underlain by a weaker clay layer have been presented. The model...
Effect of Void on Footing Behavior Under Eccentric and Inclined Loads
The effect of underground void on the behavior of strip footings subjected to eccentric and inclined loads was investigated using the finite element method of analysis. Results of the...
Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...
Performance of Different Retention Systems in Similar Soils
Performance behaviour of three deep braced excavations in a similar soil profile, in the Chicago area is described. At each site, different bracing systems were utilized. Methods used...
Interpretation of Instrumented Driven Steel Pipe Piles
This paper presents the results of a series of studies on the behavior of driven close-ended steel pipe piles. Extensive field explorations and geotechnical analyses have been carried...
Issues in Evaluating Combined Repeated Loading of Deep Foundations
The capacity and load/displacement response of deep foundations subjected to combined modes of repeated loading can be significantly different from the response under single (axial or...
Statistical Analyses of Drilled Shaft and Embedded Pole Models
In recent years a significant effort has been made by the Electric Power Research Institute (EPRI) to develop new design models, to collect and summarize existing load test data and to...
Cost Effective Pile Foundation Supports Fast Track Paper Mill
This paper decribes the generalized subsurface conditions, pile evaluation and load test program, pile and piling contractor selection, production pile installation, and quality assurance...
Combination Drilled Shaft and Driven Pile Foundation for a High-Rise Building
A case history is presented which discusses the design and construction of a combination drilled shaft and driven pile foundation which supports a high-rise in San Francisco. Drilled piers,...
A New Combined Footing and Drilled Shaft Foundation Design
A conventional belled caisson foundation installation in glacial till to support a suburban Chicago 10-story office building was stopped when test caissons revealed excessive water-bearing...
Sensitivity Study of the Cyclic Axial Capacity of a Single Pile
Evaluation of the axial capacity of an offshore pile subjected to a severe North Sea storm is presented. Effects of using different degradation criteria, upper and lower bound interaction...
Design, Construction, and Load Testing of a High Capacity Caisson
This paper describes the large diameter caisson foundation for the upstream guidewall at the Lock and Dam No. 26 (Replacement) Project. The guidewall is supported on two rows of 6-foot...
Underwater Foundations for a Jack-up Barge
Innovative underwater foundations were developed to provide a solid base for the legs of a large jack-up barge needed by General Dynamics to transport heavy components from Quonset Point,...
Axial Capacity of Pressure-Injected Piles: A Cavity Expansion Model
The application of cavity expansion theory to the development of a mathematical model for predicting the ultimate axial capacity of pressure-injected piles in cohesionless soils is presented....
Response of Concrete Island Drilling System to Ice Impact Loading
The lateral stability and load/deformation characteristics of the Concrete Island Drilling System structure under ice impact loading conditions were studied. The 300-foot-square (91.5-meter...