Full-scale Tests on Composite Connections
Tests have been carried out on eight full-scale composite connections in which the columns were manufactured of concrete-filled steel circular hollow sections (CHS). The connections were...
Steel Beams with Reinforced Concrete Stiffened Ends
For the construction of office building with long span beams, steel beams with reinforced concrete stiffened ends are being used in order to increase the stiffness. This paper describes...
Connections of Concrete Filled Steel Beams
The concrete between the steel flanges of composite beams leads to problems in the connection area. To solve these problems four new types of beam-girder and beam-column connections are...
Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...
Application and Recent Development of a Numerical Model for Composite Beams with Partial Shear Connection
This paper deals with numeric analysis of composite steel and concrete beams for loads up to the ultimate beam capacity. Two versions of a numerical model are presented addressing such...
Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...
Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...
Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...
New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...
Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...
The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...
Cathodic Protection for Protecting Prestressed Concrete
Due to the good effect of corrosion protection of reinforcing steel bars, even in concrete highly chloride contaminated, cathodic protection for concrete structure now carried out as a...
Removal, Replacement and Rehabilitation of Concrete Slabs
The project involved existing one-way slabs experiencing severe corrosion damage. The slabs were removed and replaced while salvaging the concrete beams and frame components. Significant...
Automated Design of the Steel Box Girder Guideway for the Kuala Lumpur Downtown People-Mover
Design of the Kuala Lumpur (KL) Downtown People-Mover had to be accomplished on a fast-track schedule. The system contractor assembled a team of experts from North America and Malaysia...
Generic Problems
Generic Problems are basic problems in structural mechanics that recur frequently, have been investigated experimentally and involve the behavior of elements or components found in many...
Structural Fire Resistance Design of Wood Beams and Columns: A Comparison of European and North American Practices
North American and Eurocode design methods for fire-resistive exposed wood members provide a very good example of the translation of research into practical engineering design procedures....
Concrete Beam Testing with Optical Fiber Sensors
The use of an embedded multimode optical fiber to monitor curing and load-to-failure testing of a reinforced concrete beam has been investigated. The embedding process used to network...
Shrinkage Measurements in Composite Beam Slabs
When the concrete slab on a composite beam shrinks, it is restrained by the steel beam to which it is connected. Tensile stresses, as a result, are developed in the restrained concrete...
Dynamic Response of an Infinite Beam Supported by a Fluid
The objective of this study is to investigate the dynamic response of an infinite beam supported by a fluid on one side, and subjected to dynamic loading on the other side. The fluid underneath...
Determination of In-Situ Stresses From Acoustic Emissions
Acoustic emissions (AE) are microseismic activities that are generated in concrete by cracking and damage. The rate of Acoustic Emissions, called the 'Event Rate', can provide indication...
Return to search