Assessing the True Value of Flood Control Reservoirs: The Experience of Folsom Dam in the February 1986 Flood
Over the last 40 years considerable public investments have been made in large flood control storage reservoirs throughout the U.S. and internationally. These projects were typically designed...

Probability of Bridge Failure Due to Scouring
Models to estimate depth of scour at bridge piers and abutments are available in many forms,but all of them are based on constant discharges. Their results vary widely and engineering...

Uncertainty Analysis of the FEMA Method for Alluvial Fans
Distributary flow areas such as alluvial fans, bajadas, and alluvial slopes, and alluvial plains along mountain bases pose quite different and interesting problems for the design of hydraulic...

Bridge Scour Evaluations in Washington State
Eighteen existing bridges were investigated for Washington State DOT as part of the FHWA National Scour Evaluation Program. Investigations included review of file information, site inspection,...

Variability in Solutions of Constrained Optimization Problems: Ocean Outfall Design Case
Uncertainty in optimization model resulting from parameter uncertainty has not been well studied in the hydraulics and water resources areas. To make valid decisions, knowledge of the...

Hydraulic Performance of a Flexible Curtain Used for Selective Withdrawal ? A Physical Model and Prototype Comparison
Reclamation (U.S. Bureau of Reclamation) studied a 1:120 scale undistorted density stratified physical model to develop a lightweight flexible curtain barrier that would control the outflow...

Flow Diversion in a Steep, Coarse-Bed Stream
A case study is presented of the hydraulic design of a diversion structure in a high velocity, coarse bed streamcourse. Mill Creek, a tributary to the Upper Jordan River in the southern...

New Canadian Provisions Related to the Design of Composite Beams
In this paper, the new provisions in CAN/CSA-S16.1-M89 for the design of composite beams, together with reasons for changes, are discussed. Some of the new provisions reflect results of...

Two Full-Scale Tests of Class 3 Composite Beams
This paper presents two tests of continuous composite beams comprising two 7.5 m spans and two concentrated loads close to the intermediate support. Although the cross-sections on the...

Modern Design Concept for Composite Slabs with Ductile Behaviour
Numerous tests with different types of composite slabs have been carried out in the laboratory for constructional engineering of the University of Kaiserslautern, Germany in order to determine...

Chinese Standard for Concrete-Filled Tube Columns
In this paper an outline is given of the background, the design approach and some principal features of the Chinese Specification for the Design and Construction of Concrete-filled Steel...

European Good Practice in Composite Floor Construction
Previous European experience, research and design for composite slabs with profiled steel decking are discussed. Present efforts to harmonize composite slab design and good construction...

Slim-Floor Beams: Design Criteria and Structural Behaviour
Partially concrete-encased steel beams are mostly employed due to their natural resistance to fire, but there may also be other reasons, e.g. to obtain smaller depths of construction....

A Simple Finnish Method for the Structural Fire Design of Composite Structures
The structural fire design of composite structures in Finland has previously been based on furnace tests, which are expensive and take too much time to arrange. With the increasing prominence...

Comparison of Simple Calculation Methods for the Fire Design of Composite Columns and Beams
There is a need for approximate calculation methods to do the fire design of composite structures. Several of such methods for composite beams and columns have been compared to find out...

Summary Report Design Session
The Tuesday presentations were devoted to design. Eight papers were presented in the morning general session and 17 presentations were made in 4 concurrent evening workshops. Diversity...

Semi-Rigid Joint Action in Composite Frames: Numerical Analysis and Design Criteria
The paper focusses on the analysis of semi-rigid composite frames, reporting mainly on the results of a research study which combines the experimental and theoretical approaches. Attention...

Columns of Concrete-Filled Rectangular Hollow Sections
Concrete-filled hollow sections are normally used as columns in multi-storey buildings and also in similar structures. Such columns may be filled with plain concrete with no need for any...

Recent Developments in Composite Bridges
Composite steel and concrete bridges are becoming increasingly popular, in particular for short and medium spans. This renewed interest is due first of all to the great freedom for creativity...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

 

 

 

 