Deformability of Reinforced Concrete Members
A large volume of test data has been evaluated to establish deformability of reinforced concrete beams, columns, and structural walls in the inelastic range. Experimentally observed deformation...
Structural Resistance of Slabs for Blast Loading
Results from a series of static tests on one-way reinforced concrete slabs are summarized. The slabs were loaded with a uniform pressure and tested to large deflections. Parameters varied...
Making Amends with Nature
The U.S. salmon population has been decimated in the last half-century, principally because of hydropower. In the nation's focus on alternate and clean energy sources, fish...
Cracking the Fire Code
Local building codes specify fire resistance for members in buildings and other structures, and structural engineers select materials and assemblies that have passed a standard fire resistance...
The Church on Stilts
Christ Church Cathedral is an Anglican church situated in the heart of downtown Montreal. Constructed in 1859, it is a perfect example of English neogothic architecture, characterized...
First-Order Estimation of Ko in Sands and Clays
The in-situ horizontal stress coefficient (Ko) is known to be the dominant design parameter controlling the side resistance of deep foundations....
Helical Bearing Plate Foundations for Underpinning
Helical anchor foundations have been used in construction to provide resistance against uplift and compressive loading for structures such as transmission towers, tied walls, pipelines,...
Jet Grouting to Construct a Soilcrete Wall Using a Twin Stem System
An existing coal loading pier located in Norfolk, Virginia was completed in 1961 for the purpose of loading ocean going ships. It was determined that dredging adjacent to the pier would...
Tangent Modulus of Piles Determined from Strain Data
When evaluating measurements of strain or telltale shortening of a pile subjected to loading test, precise knowledge of the 'elastic' modulus is necessary. By means of plotting and analyzing...
On the Critical Relative Displacement of Pile Shaft and Surrounding Soil
Model pile pull-out tests have been conducted to investigate the characteristics of the critical relative displacement at which the critical pile skin resistance is mobilized. Test results...
Risk Correction Factors for Bearing Capacity Analysis
In this paper bearing capacity correction factors are developed to account for the randomness in the load and soil properties. These are applied to the bearing capacity equation in the...
Human Factors and Communication Problems in Foundation Engineering
Recent findings in non-engineering fields related to human factors are reviewed with emphasis on communication difficulties. Foundation engineering tasks are discussed in the context of...
Geotechnical Judgment in Foundation Design
This paper summarizes the initial findings of a research project to investigate the judgment-making process of foundation engineers. Solutions for a typical design problem were solicited...
Bearing Pressure?SPT Correlations for Expanded Base Piles in Sand
Design of enlarged base piles is usually carried out using correlations between SPT N values and point resistance. The results of full scale load tests are used to show that base resistance...
Some Observations on Undrained Side Resistance of Drilled Shafts
A data base of 106 field load tests (65 in uplift and 41 in compression) is used to evaluate the undrained side resistance of drilled shaft foundations. The total stress or alpha (?) method...
Performance of High Capacity Caissons Founded on Decomposed Rock
The results of six load tests on large diameter caissons founded on decomposed rock are presented and analyzed. The caissons ranged from 1.5 m to 2.5 m in diameter and were 20 m to 23...
Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...
Skin Friction Load Test for Caissons in Residual Soils
Results of a load test on a drilled pier are presented. The test was performed to measure only skin friction of a 36 inch (0.91 m) diameter shaft without support at the end. The load test...
A Lateral Load Test on Seven Foot Diameter Caissons
Seven foot (2.1 m) diameter caissons (drilled shafts) were designed to support a mainline eastbound bridge and an off-ramp of Interstate Highway 70 in Glenwood Canyon, Colorado. A lateral...
Statistical Analyses of Drilled Shaft and Embedded Pole Models
In recent years a significant effort has been made by the Electric Power Research Institute (EPRI) to develop new design models, to collect and summarize existing load test data and to...
Return to search