Engineering Liabilities for Design of a Bridge That Failed During the San Fernando Earthquake
On February 9, 1971, the San Fernando Valley in Southern California experienced a major earthquake. Among the victims were two men who were killed when a bridge connector ramp of a newly...
Seismic Considerations for the Century Freeway
The Century freeway (Interstate 105), will be an 18 mile (29 km) long, six-lane facility with 2 central transit/HOV lanes, located in Los Angeles, California. The freeway alignment crosses...
Seismic Design for Sacramento Light Rail Transit System
The Sacramento Light Rail Transit Project is an 18. 5 mile system which provides the trunk line service for an integrated Bus/LRT public transportation system. Seismic design utilized...
Seismic Design of Underground Structures Southern California Metro Rail Project
The effect of earthquakes on underground structures is the imposition of an arbitrary deformation which cannot be changed by strengthening the structure. The structural design goal is...
Base Isolation Concepts for Seismic Bridge Retrofit
Failures in past earthquakes have indicated three major problem areas with existing bridges. The first is the vulnerability of existing rocker and roller type bearings and this is coupled...
Seismic Risk and Decision Analysis of Lifeline Systems
This paper provides general guidelines for performing lifeline seismic risk and decision analyses. Relevant input models are introduced as they support the performance of component and...
CSMIP Strong-Motion Instrumentation and Records from Transportation Structures?Bridges
Seven transportation structures have been instrumented by the California Strong Motion Instrumentation Program (CSMIP), including four bridges. Records (in excess of 0. 25 g maximum acceleration)...
Seismic Design of Airport Control Towers
The paper describes state-of-the-art design in seismically active areas. It includes a review of current code design parameters and specific tower design criteria. Tower design examples...
Port of Seattle Seismic Waterfront Design
This paper describes the soil seismic design process, using the design developed for a concrete apron project at Terminal 20 as an illustration. Damage by the 1965 earthquake is described....
Seismic Response of Port and Harbor Facilities
A research program compiled information regarding the behavior of port and harbor facilities during past earthquakes. The potential for significant damage to port and harbor facilities...
Intermountain Power Project Seismic Design
Coal-fueled generation units of the Intermountain Power Project are constructed in a seismically active area of Utah (UBC Zone 3). The seismic design criteria were published during the...
An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...
Seismic Risk and Reliability of Telecommunications Systems
A general method for seismic risk analysis of telecommunications sytems evaluates by statistical means the earthquake environment and the earthquake vulnerability and effects on the system...
A Systematic Approach to Conducting Seismic Margin Reviews for Nuclear Power Plants
Deviations from the current codes and standards are considered acceptable in a SMR in areas where the design criteria impose significant conservatism provided the intended function of...
Response of Subsystems on Inelastic Structures
Preliminary analyses are performed to obtain insight into the seismic response of subsystems supported on simple structures that yield during severe earthquake ground motions. Current...
Seismic Qualification of Main Control Boards by Combined Mathematical Model and In-situ Modal Test
By adjusting the stiffness of the model, mode shapes and frequencies can be matched to those from the in-situ tests, thus giving a verified and representative model. With the verified...
Seismic Evaluation of Non-Seismically Designed Existing Magnox Nuclear Power Plants
Special procedures included on-site testing with a portable shake table, low vibration testing using a structural dynamics analyser, and on-site inspections. The low vibration testing...
A Summary of the Seismic Qualification Utilities Group (SQUG) Program
In 1980, the Nuclear Regulatory Commission (NRC) designated Unresolved Safety Issue (USI) A-46 to address the seismic safety of equipment in operating nuclear power plants. In 1982, the...
Update on Impact Effects in Nuclear Plants Part I?Overview and Need for Integrated Approach
In this paper, an ASCE working group on impact effects in nuclear plants updates the review of this technology contained in a five-year-old ASCE report. In Part I, an overview is given...
Computer-Aided Design (Seismic Qualification) of Cable Tray Support System ? CADSTrays
A computer system for the analysis and design of cable tray hangers for nuclear power generating plants is discussed. An interactive language for the CADSTrayS was developed. Application...
Return to search