Development of Three Systems Operated Rev. Pump Turbine

by Anton Brcar, TOZD Inst, Ljubljana, Yugosl, TOZD Inst, Ljubljana, Yugosl,
Leopold Malovrh, TOZD Inst, Ljubljana, Yugosl, TOZD Inst, Ljubljana, Yugosl,



Document Type: Proceeding Paper

Part of: Water Power '87

Abstract:

In order to represent the development of reversible, single stage pump turbines in Yugoslavia, the three systems operated pump turbine (3SRPT) of the fourth unit of Moste hydro power plant, situated near Jesenice on the river Sava, will be briefly described. The mentioned 3SRPT was developed and realised in order to substitute the originally planned three machine pump storage set, to be built into the said plant. As a parallel aim it was intended to support development of similar machinery of larger capacities, to be designed and manufactured by national industry, for future pump storage plants being planned in the country.



Subject Headings: Energy storage | Turbines | Hydro power | Pumping stations | Power plants | Pumps | Hydraulic design

Services: Buy this book/Buy this article

 

Return to search