Microtunneling with PVC Pipe
PVC is a suitable and economical product for sewer system construction. However, in the past, utilization of PVC sewer pipe in microtunneling was impossible due to axial thrust load limitations...

Flow Study of In-Service Sanitary Sewers Rehabilitated with Insitupipe
In an effort to define the flow characteristics of sanitary sewer segments rehabilitated with Insituform under normal in-service conditions, Insituform of North America, Inc. (currently...

Joint Outfall H Relief Trunk Sewer System
The Joint Outfall 'H' Relief Trunk Sewer System consists of the construction of 11.3 kilometers (7 miles) of polyvinyl chloride lined reinforced concrete pipe varying in diameter from...

Concrete Pipe for Sanitary Sewers Corrosion Protection Update
Significant advances have been made in the last decade in the area of sanitary sewer design techniques. Some of the most important advances have been in the prediction and prevention of...

Caustic Spray for Sewer Crown Corrosion Control
A novel method to control sewer crown corrosion which involves spray application of a caustic solution to the sewer crown is described. Corrosion control using this concept is based on...

Management of Sewer System Rehabilitation for the Overflow Abatement Program in Nashville, Tennessee
To comply with a state order to abate overflows of wastewater from the sanitary sewerage system, the Nashville, Tennessee, Metropolitan Department of Water and Sewerage Services has undertaken...

Predictive Model Aids in Development of Systemwide Rehabilitation Program
Effective management of urban infrastructure requires accurate assessment of system-wide condition. Working with the City of San Jose, CH2M HILL has developed a computer model to provide...

Proactive Odor Control Using Computer Modeling
The City of Los Angeles (City) is currently designing the East Central Interceptor Sewer (ECIS) as a major relief sewer. The pipeline will convey wastewater flows that originate upstream...

Television and Scanning Sonar in Seattle Metro's Siphons and Brick Sewers
Comprehensive and often costly investigations are required in order to identify performance deficiencies of the pipeline in sewer systems, particularly when sewers in excess of 48-inch...

Trenchless Track Record
Ottawa is a leading user of trenchless technology for sewer rehabilitation projects. The municipality has nearly a decade's worth of experience with at least nine different...

Slip-Lining Solution
Grouting the annular space between a corroded sewer pipe and newly installed liner pipe is a stage of a typical sewer line rehabilitation project which contains hidden problems and difficulties....

The Big No-Dig
As part of the Boston Harbor cleanup project, engineers will have the opportunity to make a rare, side-by-side comparison of open-cut construction and no-dig technology during the Wellesley...

Estimating Urban and Suburban Sewage Flows with Assistance of GIS Technology
The Massachusetts Water Resource Authority (MWRA), an agency created by the Massachusetts legislature to provide wholesale water and sewer services to the metropolitan Boston areea, is...

Calibration and Validation of the Storm Water Management Model to the Providence Area Combined Sewer System
This paper exemplifies the calibration and validation of the EPA Storm Water Management Model (SWMM) to one drainage area within the Providence (RI) area combined sewer overflow system....

Management of Portland's Combined Sewer System
The City of Portland, Oregon, has embarked upon a two-year program to develop a long-term management program for its combined sewer system. A team of consultants is assisting the City...

When Sewer Rehab Doesn't Stop Basement Flooding
The western half of Wilmette, Illinois, is served by separate sanitary sewers. Constructed in the late 1920's, this separate sewer system was among the first installed in northeastern...

CSO Rehabilitation Strategies for Urban Areas
The USEPA national strategy for reduction of combined sewer overflows places high priority on maximizing the amount of combined wastewater that is captured and treated in the existing...

The Importance of Verified Simulation Model in a Sewerage Rehabilitation Program
In the past as structural, water quality and flooding problems occurred in a sewer system they were dealt with by crisis management. A better approach is now available using the latest...

Infrared Thermographic Sensing of Sewer Pipeline Problems
When a sewer caves in, it often takes the street, sidewalks, and surrounding buildings along for the ride. These collapses endanger public health and safety. Repairing a sewer before such...

Winter Sewer Construction in Campbell Lake
This paper discusses the winter construction for replacement of the Campbell Lake portion of the Campbell Creek C-5 Trunk (C-5 Trunk) located in Anchorage, Alaska (see Figure 1). A previous...

 

 

 

 

Return to search