Models Primarily Dependent on the Reynolds Number

by W. P. Simmons, Jr., (M.ASCE), Hydr Engr.; Div. Of Engrg. Labs., Bur. Of Reclamation, Denver, Colo.,


Serial Information: Transactions of the American Society of Civil Engineers, 1961, Vol. 126, Issue 1, Pg. 1249-1264


Document Type: Journal Paper

Abstract:

Design, construction, and operation of models of closed-conduit fluid systems, and interpretation of test data; viscous and inertia forces in flowing fluids of such models, and hence Reynolds number, are predominant factors; general rules for model size, construction, instrumentation, operating Reynolds number ranges, and data analysis are given.



Subject Headings: Construction management | Fluid flow | Reynolds number | Field tests | Inertia | Instrumentation