Evaluation of the Inter-Lok Retaining Wall System

Highway Innovative Technology Evaluation Center (HITEC), A Service Center of the Civil Engineering Research Center (CERF) of ASCE

American Society of Civil Engineers, Reston, VA
978-0-7844-0595-6 (ISBN-13) | 0-7844-0595-6 (ISBN-10), 2002, Soft Cover, Pg. 50
28 cm., CERF/IIEC Report: #40595
Out of Print: Not available at ASCE Bookstore.

Document Type: Book

Abstract: This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the INTER-LOK System for use as a technically viable, precast mechanically stabilized earth retaining wall system. The evaluation was conducted based on design, construction, performance, and quality assurance information outlined in the HITEC Protocol. The INTER-LOK System features a cross-shaped, segmental precast concrete facing panel connected to metallic rebar and anchor plate type of soil reinforcement attached to the facing panels by a keyplate that interlocks with the facing panels.

Subject Headings: Panels (structural) | Soil stabilization | Innovation | Retaining structures | Precast concrete | Reinforced concrete | Highways and roads |


Return to search