Shear Strength of High-Strength Bolts

by James J. Wallaert,
John W. Fisher,

Serial Information: Journal of the Structural Division, 1965, Vol. 91, Issue 3, Pg. 99-126

Document Type: Journal Paper

Discussion: (See full record)
Closure: (See full record)

Abstract: Double shear tests of single 7/8-in. and 1-in. high-strength bolts are reported. Altogether, ninety-six A325 bolts were tested in A7 steel jigs or in A440 steel jigs. Eighty-four A354BC, A354BD, and A490 bolts were tested in jigs made of A440 or constructional alloy steel. The effect of a number of variables on the shear strength and deformation at ultimate load was studied. The study showed that bolts tested in tension jigs had shear strengths 10% lower than bolts tested in compression jigs. Initial preload, faying surface condition, and type of connected material had no significant influence on shear strength. The shear resistance of a bolt was directly reflected by the available shear area. Also, it was found that the ultimate shear stress was approximately 73% of the tensile strength for A325 bolts tested in compression jigs and approximately 68% when these bolts were tested in tension jigs. For A354BC, A354BD, and A490 bolts, the corresponding values were 69% and 62%.

Subject Headings: Shear strength | Bolts | Shear resistance | Shear stress | Shear tests | Ultimate strength | Steel | Tension members |

Services: Buy this book/Buy this article