Experimental Determination of Sludge-Flow Parameters

by V.C. Behn,


Serial Information: Journal of the Sanitary Engineering Division, 1962, Vol. 88, Issue 3, Pg. 39-54


Document Type: Journal Paper

Abstract:

Use of rotational and capillary viscometer for experimental determination of non-Newtonian flow parameters of sewage sludges is considered; description of equipment and calibrating procedures is given together with certain experimental results; particular attention is drawn to influence of solids concentration and temperature on sludge-flow parameters.



Subject Headings: Sludge | Parameters (statistics) | Rotation | Rotational flow | Calibration | Measuring instruments | Sewage