Concrete Reactor Shield

by H.L. Meyer,


Serial Information: Journal of the Power Division, 1962, Vol. 88, Issue 2, Pg. 143-156


Document Type: Journal Paper

Abstract: Report on design and construction of reactor biological shield wall and dome for Consolidated Edison Co's Nuclear Elec Generating Station at Indian Point, NY; study to select type of arch; thermal stress considerations; construction aspects.

Subject Headings: Concrete | Construction management | Thermal loads | Walls | Nuclear reactors | Biological processes | Waste treatment | Arches | Domes (structure) | North America | United States | New York