Studies for the Lower Monumental Power Plant

by B.F. Smith,


Serial Information: Journal of the Power Division, 1961, Vol. 87, Issue 2, Pg. 1-20


Document Type: Journal Paper

Abstract: 931 Mw power plant operating at 93.5 ft head will comprise 6 Kaplan units with adjustable blades; aspects of planning and design for determining size and number of units in relation to runner diameter and other turbine characteristics and costs and benefits; comparative analysis of 60 alternate power plants.

Subject Headings: Power plants | Turbines | Benefit cost ratios | Comparative studies