Water Balance Recorder

by H.C. Aslyng,
K.J. Kristensen,

Serial Information: Journal of the Irrigation and Drainage Division, 1961, Vol. 87, Issue 1, Pg. 15-22

Document Type: Journal Paper

Discussion: (See full record)
Closure: (See full record)

Abstract: Design and construction of semi-floating lysimeter; installation consists of 2 tanks, one inside other; inner tank is partly floating and partly counterbalanced; based on change in weight, change in water level between tanks is amplified and recorded on clock-driven chart; results, based on use of such recorder.

Subject Headings: Water tanks | Construction management | Measuring instruments | Water level | Water balance |