Models Primarily Dependent on the Reynolds Number

by W. P. Simmons, Jr., (M.ASCE), Hydr Engr.; Div. Of Engrg. Labs., Bur. Of Reclamation, Denver, Colo.,

Serial Information: Journal of the Hydraulics Division, 1960, Vol. 86, Issue 6, Pg. 59-74

Document Type: Journal Paper


Design, construction, and operation of models of closed-conduit fluid systems, and interpretation of test data; viscous and inertia forces in flowing fluids of such models, and hence Reynolds number, are predominant factors; general rules for model size, construction, instrumentation, operating Reynolds number ranges, and data analysis are given.

Subject Headings: Construction management | Fluid flow | Reynolds number | Field tests | Inertia | Instrumentation

Services: Buy this book/Buy this article